  • What should I do if the high and low temperature test chamber has problems? What should I do if the high and low temperature test chamber has problems?
    Jun 23, 2025
    High and low temperature test chamber may encounter a variety of problems in the process of use, the following is a summary of potential faults and their causes from different perspectives: 1. Core system failure Temperature out of control Reason: PID control parameters are out of balance, ambient temperature exceeds the design range of the equipment, multi-zone temperature interference. Case: In a special environment workshop, the external high temperature causes the refrigeration system to overload, resulting in temperature drift. Humidity is abnormal Reason: poor water quality of humidification leads to scaling and nozzle blockage, failure of ultrasonic humidifier piezoelectric sheet, and incomplete regeneration of dehumidification desiccant. Special phenomenon: reverse condensation occurs during high humidity test, resulting in the actual humidity in the box being lower than the set value. 2. Mechanical and structural problems Air flow is disorganized Performance: There is a temperature gradient of more than 3℃ in the sample area. Root cause: the customized sample rack changed the original design air duct and the accumulation of dirt on the centrifugal fan blade led to the destruction of dynamic balance.  sealing failure New failure: the magnetic force of electromagnetic sealing door decreases at low temperature, and the silicone sealing strip becomes brittle and cracks after-70℃. 3. Electrical and control system Intelligent control failure Software level: After firmware upgrade, the temperature dead zone setting error occurs and the historical data overflow causes the program to crash. Hardware level: SSR solid state relay breakdown causes continuous heating and bus communication is subjected to inverter electromagnetic interference. Security protection vulnerabilities Hidden dangers: the synchronous failure of the triple temperature protection relay and the false alarm caused by the expiration of the refrigerant detector calibration. 4. Challenges of special working conditions Specific temperature shock Problem: -40℃ to +150℃ rapid conversion of the evaporator weld stress cracking, thermal expansion coefficient difference resulting in the failure of the observation window seal. Long-term operation attenuation Performance degradation: after 2000 hours of continuous operation, the compressor valve plate wear leads to a decrease of 15% in refrigeration capacity and drift of ceramic heating tube resistance value. 5. Environmental and maintenance impact Infrastructure adaptation Case: The power oscillation of PTC heater caused by the fluctuation of power supply voltage and the water hammer effect of cooling water system damaged the plate heat exchanger. Preventive maintenance blind spots Lesson: Ignoring the positive pressure of the box leads to water entering the bearing chamber and biofilm growth and blockage in the condensate discharge pipe. 6. Pain points of emerging technologies New refrigerant application Challenges: system oil compatibility problems after R448A replaces R404A, and high pressure sealing problems of subcritical CO₂ refrigeration systems. IoT integration risks Fault: The remote control protocol is maliciously attacked, resulting in program tampering and cloud storage failure, resulting in the loss of test evidence chain. Strategy recommendations Intelligent diagnosis: configure vibration analyzer to predict the failure of compressor bearing, and use infrared thermal imager to scan the electrical connection points regularly. Reliability design: key components such as evaporator are made of SUS316L stainless steel to improve corrosion resistance, and redundant temperature control modules are added to the control system. Maintenance innovation: implement a dynamic maintenance plan based on operating hours, and establish an annual refrigerant purity testing system。 The solutions to these problems need to be analyzed in combination with the specific model of the equipment, the use environment and the maintenance history. It is recommended to establish a collaborative maintenance mechanism including the OEM of the equipment, third-party testing institutions and user technical teams. For key test items, it is recommended to configure a dual-machine hot standby system to ensure the continuity of testing.  
    ЧИТАТЬ ДАЛЕЕ
  • What are the customization processes of non-standard test boxes? What are the customization processes of non-standard test boxes?
    Jun 20, 2025
    1. Communicate with manufacturers directly to customize requirements  operating steps : Requirement submission: clear the test object (such as headlights, batteries, sensors, etc.), test scenario (such as simulated extreme cold wading, high temperature and high pressure spraying) and industry specifications (such as automobile, military, electronics); Technology docking: provide product parameters (size, weight), environmental conditions (temperature range, impact frequency) and special requirements (such as salt spray superposition test, dynamic Angle adjustment); Confirmation of the scheme: Based on general standards such as GB, IEC and GJB, and industry specifications such as VW 80101 and ISO 16750, the manufacturer designs customized test procedures and equipment configuration schemes. 2. Adapt to the existing standard framework Manufacturers can expand or adjust based on the following criteria:  national standards : GB/T 28046.4-2011: For the climate load test of automotive electrical equipment, the core parameters such as temperature, time and circulation times of ice water impact are defined; GB/T 2423.1: Environmental test specification for general electrical and electronic products, supporting the design of calibration and verification process.  codes of practice : VW 80101-2005: Volkswagen Electric Components Test Standard, applicable to the refinement of parameters such as spray pressure and water temperature accuracy; GMW3172: General Motors global engineering standard, supporting multi-environment composite testing (such as ice water impact + salt spray corrosion); ISO 16750-4:2006: International common vehicle electrical equipment test framework, compatible with customized cycles (e.g. 100 standard or 200 enhanced). Third, optimize standards by using manufacturers' technical resources Flexible parameter adjustment: Temperature range: standard high temperature range 65~160℃, can be extended to-70℃ to +150℃; Water splashing system: support flow (3~4L/3S or 80L/min), distance (325±25mm adjustable), nozzle type (gap/matrix) and other customization; Intelligent control: the PLC system can customize the temperature switching rate (such as 20 seconds to complete the conversion from extreme cold to high temperature), data acquisition frequency and report format. Function module superposition: Compatible with multiple test requirements such as waterproof (IPX5-6) and dustproof (IP5X-6X); Support dynamic Angle spraying (15 ~75 adjustable), salt spray composite test and other complex scene simulation. 4. Ensure compliance through certification and verification Equipment calibration: the manufacturer provides half-year temperature sensor calibration service, the error is controlled within ±2℃; Third-party verification: it is recommended to certify the temperature change rate, uniformity and other indicators of customized equipment through quality inspection institutions (such as China Electric Power Research Institute, FAW test site); Data traceability: The test chamber supports USB export of test logs, which is convenient for quality traceability and standard iteration. 5. Service support and case reference Technical team: Guangdong Hongzhan cooperates with universities and research institutes to provide whole-process support from demand analysis to standard implementation; Case library invocation: You can refer to the car company case (such as 800V battery pack IPX9K test, intelligent lamp cold and hot cycle verification) to optimize and customize the standard; After-sales guarantee: customized equipment enjoys 1 year warranty and 48 hours door-to-door maintenance to ensure the stability of standard implementation.
    ЧИТАТЬ ДАЛЕЕ
  • Working principle of Guangdong Hongzhan dustproof test chamber Working principle of Guangdong Hongzhan dustproof test chamber
    Jun 20, 2025
        The Guangdong Hongzhan Dust Test Chamber is primarily used to simulate natural sand and dust environments, testing the dust resistance of various products. In industries such as electronics, automotive, and aerospace, products may face challenges from sand and dust. If a product's dust resistance is inadequate, sand and dust particles can penetrate the equipment, leading to malfunctions, performance degradation, or even damage. Therefore, accurately assessing a product's dust resistance is crucial, and the Guangdong Hongzhan Dust Test Chamber provides a reliable testing platform for companies. (1) Box structure: combination of robust and durable and sealing The test chamber is constructed from high-quality stainless steel, which not only provides excellent corrosion resistance and protection against sand and dust erosion but also ensures good sealing to prevent sand and dust leakage, maintaining the stability of the testing environment. The interior is meticulously divided into functional areas such as the sample testing zone, sand and dust circulation duct, heating system, and control system, facilitating both operation and maintenance. (2) Dust generation system: accurate simulation of dust environment This is one of the core components of the test chamber. It consists of a sand and dust storage unit, a sand and dust conveying unit, and a sand and dust dispersion unit. The storage unit can hold sand and dust of various sizes and compositions as required by the test. The conveying unit delivers the sand and dust into the test chamber using either a screw conveyor or an air conveying method. The dispersion unit ensures that the conveyed sand and dust is evenly distributed in the air, creating a stable and suitable sand and dust environment for testing, ensuring that each sample is thoroughly tested under uniform conditions. (3) Air circulation system: create stable dust airflow The air circulation system consists of a fan, ducts, and an air filter. The fan provides the necessary power to ensure the air circulates within the test chamber. The ducts guide the airflow effectively, ensuring that the air passes through the sand and dust generation system and the sample testing area, allowing the sand and dust to fully contact the samples. The air filter effectively removes sand and dust particles from the circulating air, protecting the fan and other equipment from damage and extending their lifespan. (4) Control system: intelligent and accurate operation core The control system employs an advanced programmable logic controller (PLC) and a touch screen interface. Operators can easily set and monitor test parameters, such as temperature, humidity, dust concentration, and wind speed, via the touch screen. It also features automatic adjustment capabilities, allowing it to continuously monitor and precisely adjust the various parameters inside the test chamber according to preset values, ensuring that the testing environment always meets the required standards. Additionally, the control system includes fault alarm and protection functions, which can promptly issue warning signals and take protective measures in case of any abnormal conditions, ensuring the safety of both equipment and personnel. (5) Complete workflow: efficient and rigorous testing process   During the preparation phase, operators select appropriate sand and dust particles based on the test requirements and place them in the storage device. They then clean and inspect the test chamber and properly position the samples within the testing area. Once the test chamber is activated, the sand and dust generation system begins to operate, conveying and dispersing the sand and dust into the air. The air circulation system ensures a stable flow of sand and dust air. The control system continuously monitors and adjusts various parameters to maintain a stable test environment. During the sample testing phase, the test chamber operates according to the set schedule  
    ЧИТАТЬ ДАЛЕЕ
  • What should be paid attention to in summer when using the ice water impact test chamber? What should be paid attention to in summer when using the ice water impact test chamber?
    Jun 16, 2025
      When the Guangdong Hongzhan ice water impact test chamber is used in summer, the following matters should be paid special attention to to ensure the stable operation of the equipment and the accuracy of the test results: 1. Environment and heat dissipation management   Enhance ventilation and heat dissipation High temperature in summer is easy to lead to the decrease of equipment heat dissipation efficiency. Ensure that at least 10cm space is reserved around the equipment to promote air circulation. If the equipment adopts air cooling system, the condenser surface dust should be cleaned regularly to prevent poor heat dissipation and overheating of the compressor.Control the environmental temperature and humidity. Avoid placing the equipment in the direct sunlight area. It is recommended that the laboratory temperature be kept at 25±5℃ and the humidity be lower than 85%. High temperature and high humidity environment may accelerate the accumulation of frost or condensation water on the equipment, so it is necessary to increase the dehumidification measures. 2. Refrigeration system maintenance   Water quality and tank management Bacteria are easy to breed in summer, so use deionized water or pure water to avoid hard water scaling and blocking pipes. It is recommended to change the tank water every 3 days, and empty and clean the tank before long-term disuse.Refrigeration efficiency monitoring High temperature environment may lead to overload operation of the refrigeration system. The compressor oil condition should be checked regularly to ensure sufficient refrigerant. If the water temperature exceeds the set value (such as 0~4℃), the machine should be stopped immediately for troubleshooting. 3. Frosting and defrosting treatment   Prevent frost aggravation When the humidity is high in summer, the frost rate inside the equipment may accelerate. It is recommended to perform a manual defrosting process after 10 cycles: set the temperature to 30℃ and keep it for 30 minutes, and then drain water to clean the ice crystals on the evaporator surface. Optimize the test interval to avoid continuous long-term low temperature testing. It is recommended to reserve 15 minutes of buffer time between high temperature (e.g., 160℃) and ice water shock cycle to reduce the impact of thermal stress on the equipment. 4. Adjustment of operation specifications   Parameter setting optimization According to the characteristics of the summer environment, the normal temperature recovery stage time can be shortened appropriately (the reference standard is to complete the temperature switch within 20 seconds), but it must ensure that it meets the requirements of GB/T 2423.1 or ISO16750-4 standards.Safety protection should be strengthened. Anti-freezing gloves and goggles should be worn during operation to avoid the adhesion of hands and low-temperature parts caused by sweating. Before opening the door after high temperature test, the temperature inside the box should be confirmed to be below 50℃ to prevent scalding from hot steam. 5. Emergency and long-term shutdown preparation   Fault response If the equipment has E01 (temperature out of tolerance) or E02 (water level abnormal) alarm, you should immediately cut off the power supply and contact the technical support of the manufacturer. Do not disassemble the refrigeration pipeline by yourself.Long-term protection When not used for more than 7 days, the water tank should be emptied, power should be cut off and dust cover should be covered. At the same time, power should be on for 1 hour every half a month to keep the circuit board dry.   Through the above measures, the impact of high temperature and humidity environment in summer on the ice water shock test chamber can be effectively reduced to ensure the reliability of test data and the service life of the equipment. The specific operation details should be adjusted according to the equipment manual and actual working conditions.
    ЧИТАТЬ ДАЛЕЕ
  • What are the performance of high and low temperature shock test chamber? What are the performance of high and low temperature shock test chamber?
    Jun 14, 2025
      The high and low-temperature impact test chamber is designed for reliability testing of industrial products under both high and low temperatures. It is used to evaluate the performance of components and materials in industries such as electronics, automotive, aerospace, shipbuilding, and weaponry, as well as in higher education and research institutions, under alternating cycles of high and low temperatures. The main features include: Excellent Conductivity: The alloy cable, made by adding rare earth elements and copper, iron, silicon, and other elements from China, undergoes special processing to achieve a conductivity 62% higher than that of copper. After this process, the cross-sectional area of the alloy conductor is increased by 1.28 to 1.5 times, making the cable's current-carrying capacity and voltage drop comparable to those of copper cables, effectively replacing copper with new alloy materials. Superior Mechanical Properties: Compared to copper cables, the rebound performance of the high and low-temperature impact test chamber is 40% lower, and its flexibility is 25% higher. It also has excellent bending properties, allowing for a much smaller installation radius compared to copper cables, making it easier to install and connect terminals. The special formulation and heat treatment process significantly reduce the creep of the conductor under heat and pressure, ensuring that the electrical connections of the alloy cable are as stable as those of copper cables. Reliable Safety Performance: The high and low-temperature impact test chamber has been rigorously certified by UL in the United States and has been in use for 40 years in countries like the United States, Canada, and Mexico without any issues. Based on advanced American technology, the test chamber has been tested and inspected by multiple domestic institutions, ensuring its reliable safety. Economic Performance Savings: When achieving the same electrical performance, the direct procurement cost of high and low-temperature impact test chambers is 20% to 30% lower than that of copper cables. Since alloy cables are only half the weight of copper cables and have excellent mechanical properties, using alloy cables can reduce transportation and installation costs by more than 20% in general buildings and over 40% in large-span buildings. Using high and low-temperature impact test chambers will have an immeasurable impact on building a resource-efficient society. Excellent Anti-corrosion Performance: When exposed to air at high temperatures, alloy cables immediately form a dense oxide layer that is highly resistant to various forms of corrosion, making them suitable for harsh environments. Additionally, the optimized internal structure of the alloy conductor and the use of silane cross-linked polyethylene insulation material extend the service life of alloy cables by more than 10 years compared to copper cables.                      
    ЧИТАТЬ ДАЛЕЕ
  • The basic principle of the walk-in constant temperature laboratory
    Jun 12, 2025
     The walk-in constant temperature laboratory is a crucial facility in modern scientific research and industrial experimentation. Its core principle involves maintaining a stable and reproducible experimental environment by precisely controlling temperature and environmental conditions. These laboratories typically use efficient cooling and heating systems, along with advanced temperature sensors and automatic control systems, to ensure precise temperature regulation.    In the walk-in constant temperature laboratory, temperature changes are strictly controlled within a set range. For instance, the typical operating range is from-20℃ to +60℃, which provides excellent conditions for studying the physical and chemical properties of materials. Conducting experiments in such an environment allows researchers to avoid external temperature fluctuations, ensuring more reliable and comparable results. Additionally, the walk-in design offers experimenters greater flexibility, making it easier to test large quantities or complex equipment.   In addition to temperature control, constant temperature laboratories can also regulate humidity, airflow, and other environmental factors to meet the needs of various experiments. For instance, in biological experiments, controlling humidity is equally important, as both excessively high and low humidity levels can affect biological samples. Therefore, these laboratories are typically equipped with humidity monitoring and control systems, using humidifiers or dehumidifiers to precisely manage the indoor air humidity, ensuring the reliability and consistency of experimental conditions.   Furthermore, the structural design of the walk-in constant temperature laboratory takes into account both safety and ergonomics. The equipment is meticulously arranged to allow laboratory personnel to move freely within the space, facilitating smooth experimental operations. In more advanced designs, airtight doors and isolation walls are also incorporated to ensure the independence of the experimental environment, minimizing external influences.   In summary, a walk-in constant temperature laboratory is not just a physical space; it serves as a bridge for scientific exploration. It aids researchers in investigating the performance and reaction mechanisms of materials under various complex environmental conditions, thereby driving the continuous advancement of science and technology. Whether in the development of new materials, drug testing, or climate change research, the constant temperature laboratory plays a crucial role, becoming a sacred experimental haven in the hearts of researchers.
    ЧИТАТЬ ДАЛЕЕ
  • Common faults and treatment methods of constant temperature and humidity test chamber Common faults and treatment methods of constant temperature and humidity test chamber
    Jun 11, 2025
    When operating a constant temperature and humidity test chamber, it is important to be aware of potential issues during the process and ensure proper operation. Improper handling can easily lead to equipment malfunctions. However, over time, some faults will inevitably occur. In this article, we will discuss several common faults and their solutions. Fault: If the temperature does not reach the set value during high-temperature testing, the first step is to check the electrical system and troubleshoot each component. If the temperature in the constant temperature and humidity test chamber rises too slowly, check the air circulation system to ensure the adjustment damper is functioning properly. If the temperature rises too quickly, adjust the PID settings. If the temperature rises too quickly and triggers the over-temperature protection, the controller may be faulty; in this case, replace the control panel or solid-state relay.  Fault: If the constant temperature and humidity test chamber fails to meet the low-temperature test requirements, investigate whether the temperature drops very slowly or if it stabilizes at a certain point before rising again. If the temperature drops very slowly, check if the chamber was dried before the low-temperature test to maintain dryness. Ensure the samples are not placed too densely to prevent inadequate air circulation. After ruling out these issues, consider whether the refrigeration system is malfunctioning; in such cases, seek professional repair from the manufacturer.  Fault: If the constant temperature and humidity test chamber malfunctions during operation, with the control panel displaying a fault message and an audio alarm, the operator can refer to the troubleshooting section of the equipment's user manual to identify the type of fault. Professional maintenance personnel should then perform the necessary repairs to ensure the test proceeds smoothly. Other environmental experimental equipment will have other conditions in use, which need to be dealt with according to the current situation.                                           
    ЧИТАТЬ ДАЛЕЕ
  • Две причины, по которым испытательная камера с постоянной температурой и влажностью не охлаждает Две причины, по которым испытательная камера с постоянной температурой и влажностью не охлаждает
    Jun 10, 2025
    Одна из причин 1. Поскольку температура в испытательной камере с постоянной температурой и влажностью не может поддерживаться, проверьте, может ли холодильный компрессор запуститься, когда испытательная камера работает, и может ли компрессор запуститься, когда работает оборудование для испытаний на воздействие окружающей среды, что указывает на то, что цепь от основного источника питания до каждого компрессора исправна и электрическая система не имеет проблем.2. В электрической системе нет неисправностей. Продолжайте проверять систему охлаждения. Сначала проверьте, не ниже ли нормального значения давление нагнетания и всасывания компрессора низкой температуры (R23) двух комплектов холодильных агрегатов, и не находится ли давление всасывания в состоянии вакуума, что указывает на недостаточную дозу охлаждения основного холодильного агрегата.3. Прикоснитесь рукой к выпускному и всасывающему трубопроводу компрессора R23 и убедитесь, что температура выпускного трубопровода невысокая, а температура всасывающего трубопровода не низкая (нет инея), что также указывает на недостаточное количество хладагента R23 в хосте.Другая причина: 1. Причина отказа не определена, и дальнейшее подтверждение сделано в сочетании с процессом контроля испытательной камеры постоянной температуры и влажности. Испытательная камера имеет два комплекта холодильных агрегатов.Один из них является основным, а другой — вспомогательным. Когда скорость охлаждения высока, оба блока работают одновременно в начале фазы поддержания температуры. После стабилизации температуры вспомогательный блок останавливается, а основной блок поддерживает температуру. Если хладагент R23 вытекает из основного блока, его эффективность охлаждения значительно снижается. В процессе охлаждения оба блока работают одновременно, обеспечивая стабильную температуру и постепенное снижение скорости охлаждения. На этапе изоляции, если вспомогательный блок останавливается, основной блок теряет свою функцию охлаждения, в результате чего воздух внутри испытательной камеры медленно поднимается. Когда температура достигает определенного уровня, система управления активирует вспомогательный блок для охлаждения, после чего вспомогательный блок снова останавливается. Причиной производственного сбоя была определена утечка низкотемпературного хладагента (R23) из основного блока. При проверке холодильной системы на герметичность была обнаружена трещина на штоке клапана перепускного электромагнитного клапана горячего газа длиной около 1 см. После замены соленоидного клапана и заправки системы хладагентом она вернулась к нормальной работе. Этот анализ показывает, что диагностика неисправностей следует пошаговому подходу, начиная с «внешних» аспектов и продвигаясь внутрь, затем фокусируясь на «электричестве» и, наконец, на «охлаждении». Глубокое понимание принципов работы испытательной камеры и рабочих процессов имеет важное значение для точной диагностики неисправностей.
    ЧИТАТЬ ДАЛЕЕ
  • ключевые моменты выбора высокотемпературной и низкотемпературной испытательной камеры ключевые моменты выбора высокотемпературной и низкотемпературной испытательной камеры
    Jun 06, 2025
    Восемь ключевых моментов выбора камера для испытаний на высокие и низкие температуры:1. Независимо от того, выбрано ли оно для высоко- и низкотемпературной испытательной камеры или другого испытательного оборудования, оно должно соответствовать температурным условиям, указанным в требованиях к испытаниям;2. Для обеспечения равномерности температуры в испытательной камере можно выбрать режим принудительной или непринудительной циркуляции воздуха в зависимости от теплоотдачи образцов;3. Система нагрева или охлаждения испытательной камеры высокой и низкой температуры не должна оказывать никакого воздействия на образцы.4. Испытательная камера должна быть удобной для размещения образцов на соответствующей стойке для образцов, а стойка для образцов не должна менять свои механические свойства из-за перепадов высоких и низких температур;5. Камера для испытаний на высокие и низкие температуры должна иметь защитные меры. Например: есть смотровое окно и освещение, отключение питания, защита от перегрева, различные устройства сигнализации;6. Имеется ли функция удаленного мониторинга в соответствии с требованиями заказчика;7. Испытательная камера должна быть оборудована автоматическим счетчиком, световой индикацией и регистрирующим оборудованием, автоматическим отключением и другими приборными устройствами при проведении циклических испытаний, а также иметь хорошие функции регистрации и отображения;8.В зависимости от температуры образца существует два метода измерения: температура верхнего и нижнего датчика ветра. Положение и режим управления датчика контроля температуры и влажности в испытательной камере высокой и низкой температуры можно выбрать в соответствии с требованиями заказчика к испытанию продукта для выбора соответствующего оборудования.
    ЧИТАТЬ ДАЛЕЕ